Table 1 Prediction of treatment response with oral appliance

From: Practical considerations for effective oral appliance use in the treatment of obstructive sleep apnea: a clinical review

Authors, year of publication

Number of patients

Type of titration tray

Titration criteria

AHI or RDI (/h) baseline

AHI(/h) titration PSG

AHI(/h) OA

Type of OA

OA jaw position

Prediction of treatment responder (%)

Treatment success with OA

Criterion of success

Remark

Sensitivity

Specificity

Positive predictive value

Negative predictive value

Raphaelson et al. 1998

6

N/A

    

Silencer

 

N/A

N/A

N/A

N/A

  

Case report

Dort et al. 2006

33

RCMP

Until obstructive events and snoring were eliminated

26.9 ± 18.3

N/A

N/A

Klearway

Evaluated position by titration

75

82.4

80

77.8

49%

RDI < 15/h and RDI

reduction of <30%

 

Kuna et al. 2006

21

EMA-T

・Snoring, apnea, hypopnea, were eliminated

・Maximum tolerated advancement

33.5 ± 18.3

16.4 ± 13.0

24.6 ± 17.1(titration position)

24.9 ± 18.8(final position)

Klearway

・Evaluated position by titration

・Additional advancement (final)

0 (AHI < 10)

75

(50%reduction)

55 (AHI < 10)

46

(50%reduction)

0 (AHI < 10)

46.1

(50%reduction)

92 (AHI < 10)

75

(50%reduction)

47

AHI < 15/h and

>50% reduction

inAHI

 

Tsai et al. 2004

19

RCMP

Elimination of majority of obstructive sleep apnea, hypopnea and oxygen desaturation

34.0 ± 4.88

N/A

17 ± 4.7

Klearway

Used conventional procedure

90

89

90

89

53

AHI < 15/h and AHI

reduction of >30%

and a subjective

improvement in

symptoms

 

Petelle et al. 2002

7

temporary appliance

・Significant reduction of the incidence of sleep disordered breathing

・Reaching position of maximum advancement of system

・Position causing discomfort or pain

66.9 ± 32.4

26.1 ± 20.7

19.6 ± 20.2

Herbst

Evaluated position by titration

0 (AHI < 10)

60 (AHI < 20)

100 (AHI < 10)

100 (AHI < 20)

N/A (AHI < 10)

100 (AHI < 20)

57 (AHI < 10)

50 (AHI < 20)

42.9 (AHI < 10)

68.9 (AHI < 20)

AHI < 10/h

AHI < 20/h

 

Zhou and Liu 2012

16

temporary appliance

Until the maximum AHI reduction was achieved

26.38 ± 4.13

N/A

6.58 ± 2.28 (monoblock)

9.87 ± 2.88 (SILENT NITE)

monoblock

SILENTNITE

Evaluated position by titration

N/A

N/A

N/A

N/A

68.9 (monoblock)

56.3 (SILENT NITE)

AHI < 10 and >50%

reduction in AHI

 

Remmers et al. 2013

67

RCMP

Elimination of majority of respiratory events in REM and NREM sleep in both the supine and lateral position

25.2 ± 14.8

N/A

N/A

SomnoDent

・Predicted effective target jaw position

・70% of A-P range of motion for predicted failure

86

92

94

83

58

AHI < 10 and >50%

reduction in AHI

 
  1. AHI apnea–hypopnea index, RDI respiratory disturbance index, RCMP remotely controlled mandibular protrusion