Skip to main content

Distinct polysomnographic and ECG-spectrographic phenotypes embedded within obstructive sleep apnea

Abstract

Background

The primary metric extracted from the polysomnogram in patients with sleep apnea is the apnea-hypopnea index (or respiratory disturbance index) and its derivatives. Other phenomena of possible importance such as periods of stable breathing, features suggestive of high respiratory control loop gain, and sleep fragmentation phenotypes are not commonly generated in clinical practice or research. A broader phenotype designation can provide insights into biological processes, and possibly clinical therapy outcome effects.

Methods

The dataset used for this study was the archived baseline diagnostic polysomnograms from the Apnea Positive Pressure Long-term Efficacy Study (APPLES). The electrocardiogram (ECG)-derived cardiopulmonary coupling sleep spectrogram was computed from the polysomnogram. Sleep fragmentation phenotypes used thresholds of sleep efficiency (SE) ≤ 70%, non-rapid eye movement (NREM) sleep N1 ≥ 30%, wake after sleep onset (WASO) ≥ 60 min, and high frequency coupling (HFC) on the ECG-spectrogram ≤ 30%. Sleep consolidation phenotypes used thresholds of SE ≥ 90%, WASO ≤ 30 min, HFC ≥ 50% and N1 ≤ 10%. Multiple and logistic regression analysis explored cross-sectional associations with covariates and across phenotype categories. NREM vs. REM dominant apnea categories were identified when the NREM divided by REM respiratory disturbance index (RDI) was > 1.

Results

The data was binned first into mild, moderate, severe and extreme categories based on the respiratory disturbance index of < 10, 10–30, 30–60, and greater than 60, per hour of sleep. Using these criteria, 70, 394, 320 and 188 for polysomnogram, and 54, 296, 209 and 112 subjects for ECG-spectrogram analysis groups. All phenotypes were seen at all severity levels. There was a higher correlation of NREM-RDI with the amount of ECG-spectrogram narrow band coupling, vs. REM-RDI, 0.41 vs 0.14, respectively. NREM dominance was associated with male gender and higher mixed/central apnea indices. Absence of the ECG-spectrogram sleep consolidated phenotype was associated with an increased odds of being on antihypertensive medications, OR 2.65 [CI: 1.64–4.26], p = < 0.001.

Conclusions

Distinct phenotypes are readily seen at all severities of sleep apnea, and can be identified from conventional polysomnography. The ECG-spectrogram analysis provides further phenotypic differentiation.

Background

Traditional sleep apnea morphological categories include obstructive, central, and periodic breathing/Cheyne-Stokes respiration types. Conventionally, polysomnogram (PSG) recordings are scored using 30 s epochs, into wake, rapid eye movement (REM) and non-rapid eye movement (NREM) stages. Respiratory events may be dominant in NREM or REM sleep, and at times be equally severe in both states. These events can be short, as at high altitude (25 s or less), or long, as in congestive heart failure (often over 60 s). NREM stages are further characterized into grades, N1 through N3. Alternate methods of characterizing sleep include cyclic alternating pattern (CAP) of NREM sleep (Parrino et al. 2014), and cardiopulmonary coupling (high, low and very low frequency coupling of autonomic and respiratory drives, modulated by cortical delta power) (Thomas et al. 2014). Periods of stable breathing are usually associated with N3, and always associated with non-CAP and high frequency coupling.

The apnea-hypopnea index is the result of distinct interacting biological processes, all of which can contribute to the severity of clinical sleep apnea individually and collectively. These are high loop gain, low arousal threshold, airway collapsibility, and reduced negative pressure reflex response (Owens et al. 2015; Wellman et al. 2013; Eckert et al. 2013). A computational method to derive loop gain from routine PSG data was recently proposed, based on the concept that ventilatory fluctuations from apneas/hypopneas cause opposing changes in ventilatory drive according to the loop gain (Terrill et al. 2015). It would be more useful in clinical practice if there were features on the conventional PSG or metrics computed from PSG signals which differentiated phenotypes that could guide therapy. Specifically, a high loop gain phenotype may benefit from supplemental oxygen (Wellman et al. 2008), acetazolamide (Edwards et al. 2012), or hypocapnia minimization strategies, while sedatives could be an option in those who have low arousal thresholds in NREM sleep (Smales et al. 2015).

The conventional scoring criteria for central hypopnea strongly skews the events index to obstruction-most importantly, flow-limitation is frequently seen in periodic breathing, even at high altitude (Weiss et al. 2009), a quintessential model of high loop gain sleep apnea. High loop gain apnea is NREM dominant, regardless of the admixed obstructive features (Xie et al. 2011). Quantifying NREM vs. REM dominance may thus provide a pathophysiological phenotype. The oscillatory profile of respiratory oscillations or downstream respiration-driven or associated oscillations such as heart rate variability, blood pressure or even the electroencephalogram can be quantified (Maestri et al. 2010). We present use of a ECG-derived cardiopulmonary coupling analysis to detect high loop gain apnea independent of conventional scoring.

Respiration is stable during conventional slow wave sleep. The state of the cortical sleep network seems important (Thomas 2002). Increased genioglossus tone and increases in CO2 occur during periods of stable breathing (Jordan et al. 2009), with overt hypoventilation and hypoxia if flow limitation is severe during stable breathing periods. Central sleep apnea, periodic breathing, and treatment-emergent/complex apnea are NREM sleep phenomena. Stable breathing periods have traditionally not been quantified-the focus has been on the various thresholds and associations to determine clinically significant apnea or hypopnea. We quantified stable breathing using the ECG-based cardiopulmonary coupling technique, as described below. Stable breathing periods in apnea patients will likely demonstrate increased upper airway resistance. Despite the strong link between stable breathing and stage N3, the relationship is not exclusive: specifically, most periods of stable breathing occur in stage N2, even in those patients with no scored N3 sleep.

It is a common clinical observation that some patients with sleep apnea have disproportionate sleep fragmentation, and some with severe apnea demonstrate relatively intact macro-architecture of sleep. We used a well characterized sleep apnea clinical trial dataset, the Apnea Positive Pressure Long-term Efficacy Study (APPLES) (Kushida et al. 2006), to determine if at every severity of sleep apnea, discernable sleep and sleep apnea phenotypes exist. We used conventional polysomnogram metrics complemented with an electrocardiogram (ECG)-based analysis that can detect periods of stable breathing (Thomas et al. 2005) and pathological respiratory chemoreflex activation (Thomas et al. 2007a).

Methods

Database

The APPLES data was obtained in Alice™ and European Data Format, the latter was used for ECG-spectrogram analysis. He study randomized just over 1000 subjects to continuous positive airway pressure (CPAP) or placebo CPAP. A total of 972 baseline diagnostic polysomnograms were obtained; a subset of the data was embargoed by the primary study for administrative reasons. The following subjective and objective measures of sleepiness, mood and cognition were available: Hamilton Depression Scale, Epworth Sleepiness Scale, Stanford Sleepiness Scale, Paced Auditory Serial Addition Test, Psychomotor Vigilance Test Median and Mean reaction times, Maintenance of Wakefulness Test, and Short Term Working Memory.

Polysomnogram scoring

Standard scoring was done based on pre-2007 criteria on the polysomnogram data, generating respiratory, arousal, and sleep stage indices. The respiratory disturbance index used in the APPLES is equivalent to the current hypopnea definition with a 3% oxygen desaturation and/or arousal (Berry, 2017). We combined stage III and IV as the equivalent of current stage N3 (slow wave sleep). In this paper, we use the current terminology and designations to keep with current terms used in publications, though stage N1 and N2 will show some differences, typically greater N1, if the data were re-scored. A breakdown of REM and NREM RDI was also available. The characteristics of the full study population have also been published (Kushida et al. 2006; Quan et al. 2011). NREM vs. REM dominance was computed as the ratio of NREM/REM RDI; a value > 1 was considered NREM dominance.

ECG-spectrogram analysis

The cardiopulmonary coupling (CPC) analysis (Figs. 1 and 2) of the ECG signal was performed as previously described in detail (Thomas et al. 2005). Briefly, heart rate variability and ECG-derived respiration (EDR; amplitude variations in the QRS complex due to shifts in the cardiac electrical axis relative to the electrodes during respiration and changes in thoracic impedance as the lungs fill and empty) are extracted from a single channel of ECG. Time series of normal-to-normal sinus (N-N) intervals and the time series of the EDR associated with these NN intervals are then extracted from the original R-R (QRS to QRS) interval time series. Outliers due to false or missed R-wave detections are removed using a sliding window average filter with a window of 41 data points and rejection of central points lying outside 20% of the window average. The resulting NN interval series and its associated EDR are then resampled using cubic splines at 2 Hz. The cross-spectral power and coherence of these two signals are calculated over a 1024 sample (8.5 min) window using the Fast Fourier Transform applied to the 3 overlapping 512 sample sub-windows within the 1024 coherence window. The 1024 coherence window is then advanced by 256 samples (2.1 min) and the calculation repeated until the entire NN interval/EDR series is analyzed. For each 1024 window the product of the coherence and cross-spectral power is used to calculate the ratio of coherent cross power in the low frequency (0.01–0.1 Hz.) band to that in the high frequency (0.1–0.4 Hz.) band. The logarithm of the high to low frequency cardiopulmonary coupling ratio (log [HFC/LFC]) is then computed to yield a continuously varying measure of cardiopulmonary coupling. The graph of the amplitude of cardiopulmonary coupling at relevant frequencies (ordinate) vs. time (abscissa) provides a sleep spectrogram. Since the period of central apnea can be as slow as 120 s or longer, we used the frequency band between 0.006 and 0.1 Hz to define narrow spectral band e-LFC (putative central sleep apnea, periodic breathing, or complex sleep apnea). We required (1) a minimum power in this band of 0.3 normalized units and (2) that the coupling frequency of each pair of consecutive measurements remains within 0.0059 Hz of each other over 5 consecutive sampling windows (totaling 17 continuous min). Periods of e-LFC not meeting these criteria were defined as broad spectral band e-LFC (putative pure obstructive sleep apnea). The amounts of broad and narrow spectral band coupling in e-LFC bands were then expressed as the percentage of windows detected in relation to the total sleep period. Thus, the narrow spectral band e-LFC identified periods with oscillations that have a single dominant coupling frequency, suggesting central sleep apnea or periodic breathing (Thomas et al. 2007a). The broad spectral band e-LFC identified periods with oscillations that have variable coupling frequencies, suggesting an alternative mechanism, which we posited was dominance of anatomic upper airway obstructive processes. As it takes 17 min of continuous narrow-band cardiopulmonary coupling to reach the detection threshold, we estimated that this would be approximately equal to an averaged central apnea index of 5/h of sleep, assuming 6 h of sleep and a periodic breathing cycle length of approximately 35 s. Finally, using the mean frequency and percentage of total sleep time in state, the LFC and e-LFC oscillation indices and mean cycle time were computed.

Fig. 1
figure 1

Algorithm outline for the ECG-cardiopulmonary coupling analysis. The schema describes the analytic pathway for cardiopulmonary coupling analysis, using two distinct data streams embedded within the ECG: autonomic drive via heart rate variability and respiratory ECG-R amplitude modulation as a surrogate of respiration

Fig. 2
figure 2

Sample ECG-spectrogram. Note high, low and very low frequency coupling (HFC, LFC and VLFC respectively) and the clear separation in signal space of HFC from LFC/VLFC. HFC is the ECG-spectrogram signal biomarker of stable breathing and stable sleep. VLFC reflects REM or wake

Phenotype designation

The data was binned first into mild, moderate, severe and extreme categories based on the respiratory disturbance index (respiratory events scored with a 3-s arousal or 4% oxygen desaturation) of < 10, 10–30, 30–60, and greater than 60, per hour of sleep. These severity groups were chosen to capture a range from mild to most severe. For example, ≥ 60 could be considered “extreme”, but would be subsumed otherwise if ≥ 30 only was used as a “severe” cut off. Phenotype percentages were based on 972 and 617 subjects for polysomnographic and spectrographic phenotyping, respectively. Table 1 lists the criteria for the phenotypes. Figure 3 shows that individual phenotypes may or may not coexist. The criteria for a sleep fragmentation phenotype was based on clinical reasonableness, as no formal criteria exist. On a polysomnogram, a “fragmentation phenotype” can be suggested by prolonged return to sleep following arousals/awakenings, low sleep efficiency (<70%), high N1, and high wake after sleep onset (Thomas 2014). There is too little N3 to be a useful discriminatory metric. We choose a high frequency coupling % of ≥ 50 and ≤ 30 as thresholds for consolidated and fragmented phenotypes, guided by data from healthy individuals (Thomas et al. 2005) and analysis of the Sleep Heart Health Study (Thomas et al. 2014; Thomas et al. 2009).

Table 1 Phenotype Definitions
Fig. 3
figure 3

Patterns of sleep fragmentation phenotype based on sleep efficiency. The upper hypnogram shows rapid sleep-wake transitions from severe sleep apnea, while the lower hypnogram shows nearly the same sleep efficiency but with consolidated periods of wake separated by consolidated periods of sleep. The % N1 is markedly increased in the patient with rapid transitions (44.2%). Thus, individual phenotypes can mix and match. ROx: raw oximetry. EV: respiratory events. OxEv: Oximetry desaturation events. Hyp: sleep stage hypnogram

Statistical analysis

Summary measures were mean/standard deviations for continuous measures, and proportions for categorical measures. T-tests were used to assess differences between NREM and REM dominance ratios. Logistic Regression with adjustment for age, gender, BMI, ethnicity and overall RDI assessed Odds Ratios for different phenotypic categories, with the following predictor categories: central apnea index, presence/absence of narrow band coupling, and the ECG-spectrogram sleep fragmentation category. The full multiple regression model assessing associations of individual phenotypes adjusted for age, gender, ethnicity, body mass index and sleep apnea severity (RDI), and total sleep time for PSG-based metrics. Pearson’s Correlation estimated relationships between ECG spectrogram and polysomnogram indices. Chi2 test was used to assess significant differences of phenotypes across categories of apnea severity.

Results

Demographics and polysomnography

The demographic and polysomnographic characteristics of the subjects are described in Table 2, the 972 with polysomnogram and the 671 with ECG-spectrogram analysis. There were no significant differences. Loss of ECG-spectrogram analysis occurred from the following reasons: 1) Movement artifact or gaps, including bathroom breaks, ≥ 10 min. Such dropouts made up the majority (86%) of lost data. 2) Signal drop out, e.g., displaced electrode. There were no significant differences between included and excluded subjects, in terms of demographics and clinical conditions such as hypertension and diabetes. Central sleep apnea, defined as CAI ≥5/h of sleep, was noted in 47/972 (5.1%) and 30/671 (4.5%), respectively.

Table 2 Polysomnographic and Demographic features

ECG-spectrogram characteristics

Characteristics of the APPLES is described in Table 3. The mean cycle time calculated by the ECG spectrogram was just over 30 s. There was a higher correlation of NREM-RDI with the amount of narrow band coupling, vs. REM-RDI, 0.41 vs 0.14, respectively (Table 4).

Table 3 ECG-spectrogram features in the APPLES
Table 4 Correlation (r) of ECG-spectrogram and PSG respiratory indices

Polysomnographic and spectrographic phenotypes

There were 70, 394, 320 and 188 subjects in the four categories of increasing severity (Tables 5 and 6). The corresponding sample size with the ECG-spectrogram was 54, 296, 209 and 112, respectively. The proportion of clinical phenotypes were different across severity in some but not all categories (Table 5). Specifically, the ECG-spectrogram categories did not show significant changes across severity, but the polysomnogram phenotype categories did. While no subject in the mild category had central sleep apnea, 8% did in the most severe category.

Table 5 Polysomnographic and spectrographic metrics across apnea severity groups (mean ± SD)
Table 6 Phenotypes across sleep apnea severity categories

NREM vs. REM dominance

NREM dominance of sleep apnea was observed in 26.1% (242/671) of the cohort. The characteristics of the NREM vs. REM dominance groups are in Table 7. Notable features associated with NREM dominance are: 1) male gender; 2) greater degrees of sleep fragmentation; 3) more severe sleep apnea; 4) higher central and mixed apnea indices. The presence of narrow band coupling predicted NREM dominance, Odds Ratio 1.56 [CI: 1.1–2.29, p: 0.021], adjusted for age, gender, ethnicity, body mass index and overall RDI. Table 8 shows the predictors of NREM dominance, which included sleep fragmentation (positively) and ECG-sleep consolidation (negatively), adjusted for age, gender, BMI, ethnicity, and overall RDI.

Table 7 NREM vs. REM dominance: clinical and polysomnographic features
Table 8 Predictors of NREM dominance

Predictors of phenotypes

Correlation between the measures of sleep fragmentation or consolidation are to be expected. In our sample, the following were the r values, all p: < 0.001: WASO-N1 (0.33), WASO-sleep efficiency (−0.93), and N1-sleep efficiency (−0.31). The categories of fragmentation or consolidation were related but also showed independence. After adjusting for age, gender, race, body mass index, total sleep time and sleep apnea severity, using logistic regression, the following were noted: 1) Sleep fragmentation: a) efficiency-N1: OR 1.89 [CI: 0.94–3.79], p: 0.072; b) efficiency-WASO: OR 4.19 [1.18–14.86], p: 0.027; c) N1-WASO: OR 2.18 [1.24–3.83], p: 0.007. 2) Sleep consolidation: a) efficiency-N1: OR 2.6 [CI: 1.68–4.03], p: < 0.001; b) efficiency-WASO: OR 50.19 [24.26–103.84], p: < 0.001; c) N1-WASO: OR 1.96 [0.97–3.05], p: 0.07.

In a multiple regression analysis adjusted for age, gender, ethnicity, body mass index and sleep apnea severity (RDI), age was a consistent positive predictor of sleep efficiency, wake after sleep onset and N1 fragmentation categories. Coefficient ± SE, p was 0.007 ± 0.001; p: < 0.001; 0.015 ± 0.001, p: < 0.001; and 0.004 ± 0.001, p: < 0.001, respectively. Male sex was predictive for N1 sleep fragmentation category; 0.06 ± 0.03, p: 0.020. Central apnea category was predicted by age (0.001 ± 0.001 per year, p: 0.024) and male sex (0.048 ± 0.016, p: 0.003).

In a logistic regression analysis (Table 9), the central apnea category increased the odds of ECG-spectrogram fragmentation phenotype, and reduced that of the N1 PSG consolidation phenotype. The presence of narrow band coupling increased the odds of the N1 and the ECG-spectrogram fragmentation phenotypes, while reducing the odds of the ECG-spectrogram consolidation phenotype. Finally, the ECG-spectrogram fragmentation phenotype increased the odds of the N1 fragmentation phenotype and reduced the odds of the N1 and WASO consolidation phenotypes.

Table 9 Predictors of Primary Phenotypes

Cycle time influences

The cycle time of LFC (30.4 ± 8.1) and e-LFC (31 ± 8.4) was not significantly different across various sleep fragmented or consolidated phenotypes, or NREM vs. REM dominance (the latter 31 ± 8.8 vs. 31 ± 8.2, p: 0.99). Those with narrow-band coupling had a shorter cycle time than those without, 27.5 ± 5.7 vs. 32.8 ± 8.8 s, p: < 0.001 for LFC, and 27.8 ± 6.8 vs. 32.6 ± 8.7 s, p: < 0.001, for e-LFC.

Phenotypes and clinical baseline covariates

The total Epworth Sleepiness Scale was modified by NREM vs. REM dominance: 9.2 ± 4.2 vs. 10.2 ± 4.3, t-test, p: 0.009. A multiple regression with adjustment for age, gender, body mass index, ethnicity, and total RDI remained significant: Beta Coefficient -0.003 ± SE 0.38, p: 0.009. Absence of the ECG-spectrogram sleep consolidated phenotype was associated with an increased odds of being on antihypertensive medications, OR 2.65 [CI: 1.64–4.26], p: < 0.001, adjusted for age, gender, BMI, total sleep time, and slow wave sleep (pre 2007 stages S3 + S4). The difference in high frequency coupling in those with and without the ECG-spectrogram consolidated phenotype was substantial and clinically meaningful, 50.7 ± 22.4 vs. 37.3 ± 21.8% total sleep time. Evening and morning systolic and diastolic blood pressures were, however, not significantly different. Other phenotypes at baseline including all cognitive measures did not show differences in clinical covariates. The evening systolic blood pressure was higher in the NREM-dominant group, 125.3 ± 14.7 vs. 122.6 ± 14.7 mm Hg, but was no longer significant after adjustment for age.

CPAP compliance

Use of CPAP during the last month of the 6-month trial was 4.2 ± 2.2 h, and 3.9 ± 2.1 h across the entire duration. The percentage of use of CPAP for 4 or more hours, average of all subjects, was 55 ± 20%.

Mean compliance across the 6 months was lower in those with the sleep fragmentation-N1 group, 3.6 ± 2 vs. 4 ± 2.1 h. Other categories had no impact.

Discussion

The results of our analysis show that discernable phenotypes are present within what is otherwise considered generic obstructive sleep apnea. Fragmented and consolidated phenotypes are see at milder and more severe extremes of obstructive sleep apnea, using both conventional and computed analysis of polysomnogram signals. Presumptive high loop gain phenotypes, central sleep apnea on polysomnography and narrow-band coupling on ECG-spectrogram, are associated with greater degrees of sleep fragmentation. Stage dominance, NREM vs. REM shows clear differences. Cycle time metrics provide further insight into pathological interactions that result in a final common output, that of an apnea-hypopnea index. Several aspects of extractable phenotypes provide novel insights into sleep apnea.

Periods of stable breathing during NREM sleep

Some clues to the nature of this phenomenon can be gained from the concept of NREM sleep bimodality. The first clue came from the description of CAP and non-CAP from Italian researchers in the mid 1980’s (Terzano et al. 1985). CAP and non-CAP periods occur across NREM sleep. CAP occurs in N1 and parts of N2; non-CAP occurs in parts of N2 and most of N3 (Parrino et al. 2014). Subsequently, the autonomic and respiratory associations of CAP/non-CAP were described (Kara et al. 2003). Finally, the description of the cardiopulmonary coupling technique showed that NREM sleep has bimodal characteristics in health and disease. High frequency coupling is associated with high delta power, non-CAP EEG, stable breathing, strong sinus arrhythmia, and blood pressure dipping (Thomas et al. 2014). Low frequency coupling is associated with unstable breathing, cyclic variation in heart rate, CAP EEG, and blood pressure non-dipping. Thus, stable breathing periods reflect natural integrated network states of the brain. Benzodiazepines and related drugs increase non-CAP (Parrino et al. 1997; Terzano et al. 1995), and may be expected to increase stable breathing periods. Zolpidem increases blood pressure dipping (Huang et al. 2012), and could do so through the induction of stable NREM periods.

The proportion of stable breathing periods will impact the computed apnea-hypopnea index, as these periods do not contribute to the metric. Varying proportions of stable breathing on a night to night basis can contribute to night to night variability of the apnea-hypopnea index. The fact that even at the most severe end of the spectrum there are patients with consolidated sleep by any measure suggests that this is an individual trait.

NREM vs. REM dominance

In general, periodic breathing and hypocapnic central apnea does not occur in REM sleep (exception, a patient with congestive heart failure who demonstrates periodic breathing during wake state). NREM dominance is well described in idiopathic central sleep apnea (Quadri et al. 2009), periodic breathing associated with heart failure or stroke (Hanly et al. 1989), opiate-induced sleep apnea (Walker et al. 2007), and high altitude periodic breathing (Thomas et al. 2007b). NREM dominance is also a feature of complex apnea/treatment-emergent central sleep apnea, regardless of the exact definition used (Rao & Thomas 2013). In the APPLES data, NREM dominance was associated with greater severity of disease, male sex, and increased central/mixed apneas, even if less than the conventional threshold for central sleep apnea was used (which requires ≥ 50% of all events to be central). It is possible that NREM dominant obstructive sleep apnea reflects high loop gain (Rao & Thomas 2013; Stanchina et al. 2015), and is thus a recognizable phenotype from standard polysomnograms even without further computational analysis.

Accurate estimation of central sleep apnea from clinical polysomnograms

In the APPLES data, the amount of central apnea/presumed high loop gain features estimated by conventional features vs. ECG-spectrogram diverged markedly. The American Academy of Sleep Medicine (AASM) criteria defines a central apnea as an oronasal flow drop by > 90% of baseline, lasting 10 s, in the absence of inspiratory effort. (Iber & American Academy of Sleep Medicine 2007) A central hypopnea requires proportional and concordant flow and effort reduction and absence of snoring (except possibly at recovery) and flow-limitation. However, events both at sea level (often) and high altitude (always) in patients with positive pressure induced or amplified respiratory instability have short cycles that are less than 30 s. If 40 s is a requirement, then these short-cycle hypopnea events will be falsely characterized as obstructive. The International Classification of Sleep Disorders (ICSD)-3 specifies that these should make up ≥ 50% of all scored events, so substantial central events can still carry an obstructive summary label.

The scoring guidelines state that flow limitation excludes a “central hypopnea” in the scoring manual yet several lines of evidence argue strongly against this: a) at high-altitude, a pure chemoreflex form of sleep apnea, flow-limitation occurs frequently; b) studies using esophageal manometry and endoscopy show that pharyngeal airway narrowing and occlusion occur during central apneas in healthy individuals as well as in patients with heart failure. c) the airway can close during polysomnographic central apnea; (Badr 1996; Badr et al. 1995) d) central hypopneas demonstrate flow-limitation (Badr et al. 1995; Sankri-Tarbichi et al. 2009; Guilleminault et al. 1997; Dowdell et al. 1990). Despite the known presence of flow limitation and airway narrowing during both central and obstructive events (Dempsey et al. 2014), hypopnea scoring is biased towards obstructive disease (Rao & Thomas 2013; Eckert et al. 2007; Javaheri & Dempsey 2013).

The APPLES scoring did not include central hypopneas and thus likely underestimated high loop gain features. The ECG-spectrogram analysis showed that central/periodic breathing-type oscillations were present in nearly one third of the APPLES cohort, and that this signal biomarker was more closely associated with NREM than REM RDI. The shorter cycle time in the e-LFCNB group is consistent with short-cycle periodic breathing being associated with NREM dominant sleep apnea and high loop gain (Gilmartin et al. 2005).

A sleep fragmentation phenotype

A distinct sleep fragmentation phenotype was evident at all severities of obstructive sleep apnea. This result is generally consistent with the variability of arousal phenomena in sleep apnea, contributing to amplification of disease, especially in NREM sleep (Eckert & Younes 2014). While low arousal threshold is a measurable sleep apnea phenotype (Eckert et al. 2013), the return to sleep after arousal is probably just as important. Recovery from arousal is a continuous process of variable dynamics (Younes & Hanly 2016; Younes et al. 2015), and if delayed, the epoch will be scored as wake or N1/S1. If this phenotype is a trait, sedatives may have a role in management, similar to reducing the apnea-hypopnea index in NREM sleep in those with low arousal threshold (Smales et al. 2015). As no physiological sleep apnea trait estimates were performed in the APPLES, concordance or discordance of a low arousal vs. sleep fragmentation phenotype could not be determined. High N1 fragmentation phenotype was associated with reduced compliance.

A need for improved phenotyping

From a diagnostic standpoint, there is minimal relationship of the AHI with subjective or objective sleepiness measurements (Gottlieb et al. 1999; Eiseman et al. 2012). From a treatment standpoint, predicting paradoxical PAP response (complex apnea) is not reliably predicted standard metrics, but is predicted by CPC metrics (Thomas et al. 2007a). Diagnostic phenotyping is important for appropriate clinical case detection, epidemiology, and clinical trial planning purposes. Treatment phenotypes should reasonably focus on response to therapy, positive pressure or otherwise. Persistence of phenotypes or conversion of one phenotype to another can have clinical implications. For example, a fragmentation phenotype which persists may benefit from sedatives, cognitive behavioral therapy or re-looking at therapeutic precision, while a fragmentation to consolidated phenotype shift implies therapeutic success. Therapies can target driving phenotypes to more desirable ones, e.g., acetazolamide for a high loop gain/NREM-dominant phenotype (Edwards et al. 2012).

Phenotypes and clinical covariates

The slightly lower subjective sleepiness score in NREM dominant sleep apnea is largely in keeping with lesser degrees of subjective sleepiness in patients with strong respiratory chemoreflex activation. Heart rate variability and muscle sympathetic nerve activity are inversely related to subjective sleepiness in heart failure (Taranto Montemurro et al. 2012; Taranto Montemurro et al. 2014). The tight link of the respiratory chemoreflex and sympathetic centers in the brainstem is one plausible explanation-that these individuals have heightened sympathetic drive for a given degree of sleep apnea. Increased hypertension risk in those with reduced high frequency coupling, a signal biomarker of stable breathing and sleep, could reflect the impact of longer periods of stable breathing and the associated vagal dominance, even in those with sleep apnea, on overall blood pressure control.

The relative lack of impact of the various phenotypes on any measure of cognition was a surprise. This result may reflect the characteristics of the APPLES population which resulted in a negative result in the primary study (CPAP vs. placebo CPAP). The mechanisms which impair cognition and mood in sleep apnea are not well understood, and likely reflect an interaction of the stressor and individual resilience factors. Our result may also reflect our current inability to identify the factors associated with a certain apnea-hypopnea index which determines an adverse impact on brain function. The APPLES follow-up data we aim to analyze may provide additional clues.

Limitations of the analysis

The primary limitation of the presented analysis is that the impact of phenotypes on outcomes cannot be determined. The criteria for various phenotype categories were necessarily arbitrary but are “clinically reasonable”. Moreover, if these patterns are maintained over time despite positive pressure therapy is important to know, and will need further follow-up analysis of the APPLES data. Body position effects were not quantified. Respiratory Effort Related Arousal events were not scored in the APPLES, and could alter some of our conclusions. Careful scoring of periodic breathing without the filter of flow limitation may provide higher estimates of loop gain than standard scoring. A more detailed analysis of compliance metrics across the 6 months, including differentiating sham vs. real CPAP, will be required to establish an impact of phenotypes described here.

Conclusions

Distinct phenotypes of fragmentation, consolidation, NREM vs. REM dominance, and high loop gain can be identified in the conventional polysomnogram, by both standard scoring and estimates of cardiopulmonary coupling. Baseline clinical characteristics including cognition were not impacted by the phenotypes. The impact of these phenotypes on treatment clinical outcomes require analysis and research.

Abbreviations

AASM:

American Academy of Sleep Medicine

APPLES:

Apnea Positive Pressure Long-term Efficacy Study

BMI:

Body mass index

CAI:

Central apnea index

CPAP:

Continuous positive airway pressure

CPC:

Cardiopulmonary coupling

CSR:

Cheyne-Stokes respiration

ECG:

Electrocardiogram

EEG:

Electroencephalogram

HFC:

High frequency coupling

LFC:

Low frequency coupling

NREM:

Non-rapid eye movement

PSG:

Polysomnogram

RDI:

Respiratory disturbance index

REM:

rapid eye movement

SC:

Sleep consolidation

SF:

Sleep fragmentation

VLFC:

Very low frequency coupling

WASO:

Wake after sleep onset

References

  • Badr MS. Effect of ventilatory drive on upper airway patency in humans during NREM sleep. Respir Physiol. 1996;103:1–10.

    Article  CAS  PubMed  Google Scholar 

  • Badr MS, Toiber F, Skatrud JB, Dempsey J. Pharyngeal narrowing/occlusion during central sleep apnea. J Appl Physiol. 1995;78:1806–15.

    CAS  PubMed  Google Scholar 

  • Berry RB BR, Gamaldo CE, Harding SM, Lloyd RM, Marcus CL and Vaughn BV for the American, Academy of Sleep Medicine. The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications VwaoD, Illinois: American Academy of Sleep Medicine. 2017 Version 2.4.

  • Dempsey JA, Xie A, Patz DS, Wang D. Physiology in medicine: obstructive sleep apnea pathogenesis and treatment--considerations beyond airway anatomy. J Appl Physiol. 2014;116:3–12.

    Article  CAS  PubMed  Google Scholar 

  • Dowdell WT, Javaheri S, McGinnis W. Cheyne-Stokes respiration presenting as sleep apnea syndrome. Clinical and polysomnographic features. Am Rev Respir Dis. 1990;141:871–9.

    Article  CAS  PubMed  Google Scholar 

  • Eckert DJ, Younes MK. Arousal from sleep: implications for obstructive sleep apnea pathogenesis and treatment. J Appl Physiol (1985). 2014;116:302–13.

    Article  CAS  Google Scholar 

  • Eckert DJ, Jordan AS, Merchia P, Malhotra A. Central sleep apnea: Pathophysiology and treatment. Chest. 2007;131:595–607.

    Article  PubMed  PubMed Central  Google Scholar 

  • Eckert DJ, White DP, Jordan AS, Malhotra A, Wellman A. Defining phenotypic causes of obstructive sleep apnea. Identification of novel therapeutic targets. Am J Respir Crit Care Med. 2013;188:996–1004.

    Article  PubMed  PubMed Central  Google Scholar 

  • Edwards BA, Sands SA, Eckert DJ, et al. Acetazolamide improves loop gain but not the other physiological traits causing obstructive sleep apnoea. J Physiol. 2012;590:1199–211.

    Article  PubMed  PubMed Central  Google Scholar 

  • Eiseman NA, Westover MB, Mietus JE, Thomas RJ, Bianchi MT. Classification algorithms for predicting sleepiness and sleep apnea severity. J Sleep Res. 2012;21:101–12.

    Article  PubMed  Google Scholar 

  • Gilmartin GS, Daly RW, Thomas RJ. Recognition and management of complex sleep-disordered breathing. Curr Opin Pulm Med. 2005;11:485–93.

    Article  PubMed  Google Scholar 

  • Gottlieb DJ, Whitney CW, Bonekat WH, et al. Relation of sleepiness to respiratory disturbance index: the Sleep Heart Health Study. Am J Respir Crit Care Med. 1999;159:502–7.

    Article  CAS  PubMed  Google Scholar 

  • Guilleminault C, Hill MH, Simmons FB, Powell N, Riley R, Stoohs R. Passive constriction of the upper airway during central apneas: fiberoptic and EMG investigations. Respir Physiol. 1997;108:11–22.

    Article  CAS  PubMed  Google Scholar 

  • Hanly PJ, Millar TW, Steljes DG, Baert R, Frais MA, Kryger MH. Respiration and abnormal sleep in patients with congestive heart failure. Chest. 1989;96:480–8.

    Article  CAS  PubMed  Google Scholar 

  • Huang Y, Mai W, Cai X, et al. The effect of zolpidem on sleep quality, stress status, and nondipping hypertension. Sleep Med. 2012;13:263–8.

    Article  PubMed  Google Scholar 

  • Iber C, American Academy of Sleep Medicine. The AASM manual for the scoring of sleep and associated events: rules, terminology, and technical specifications. Westchester: American Academy of Sleep Medicine; 2007.

    Google Scholar 

  • Javaheri S, Dempsey JA. Central sleep apnea. Compr Physiol. 2013;3:141–63.

    CAS  PubMed  Google Scholar 

  • Jordan AS, White DP, Lo YL, et al. Airway dilator muscle activity and lung volume during stable breathing in obstructive sleep apnea. Sleep. 2009;32:361–8.

    PubMed  PubMed Central  Google Scholar 

  • Kara T, Narkiewicz K, Somers VK. Chemoreflexes--physiology and clinical implications. Acta Physiol Scand. 2003;177:377–84.

    Article  CAS  PubMed  Google Scholar 

  • Kushida CA, Nichols DA, Quan SF, et al. The Apnea Positive Pressure Long-term Efficacy Study (APPLES): rationale, design, methods, and procedures. J Clin Sleep Med. 2006;2:288–300.

    PubMed  Google Scholar 

  • Maestri R, La Rovere MT, Robbi E, Pinna GD. Fluctuations of the fractal dimension of the electroencephalogram during periodic breathing in heart failure patients. J Comput Neurosci. 2010;28:557–65.

    Article  PubMed  Google Scholar 

  • Owens RL, Edwards BA, Eckert DJ, et al. An integrative model of physiological traits can be used to predict obstructive sleep apnea and response to non positive airway pressure therapy. Sleep. 2015;38:961–70.

    PubMed  PubMed Central  Google Scholar 

  • Parrino L, Boselli M, Spaggiari MC, Smerieri A, Terzano MG. Multidrug comparison (lorazepam, triazolam, zolpidem, and zopiclone) in situational insomnia: polysomnographic analysis by means of the cyclic alternating pattern. Clin Neuropharmacol. 1997;20:253–63.

    Article  CAS  PubMed  Google Scholar 

  • Parrino L, Grassi A, Milioli G. Cyclic alternating pattern in polysomnography: what is it and what does it mean? Curr Opin Pulm Med. 2014;20:533–41.

    Article  PubMed  Google Scholar 

  • Quadri S, Drake C, Hudgel DW. Improvement of idiopathic central sleep apnea with zolpidem. J Clin Sleep Med. 2009;5:122–9.

    PubMed  PubMed Central  Google Scholar 

  • Quan SF, Chan CS, Dement WC, et al. The association between obstructive sleep apnea and neurocognitive performance--the Apnea Positive Pressure Long-term Efficacy Study (APPLES). Sleep. 2011;34:303–14B.

    PubMed  PubMed Central  Google Scholar 

  • Rao H, Thomas RJ. Complex sleep apnea. Curr Treat Options Neurol. 2013;15:677–91.

    Article  PubMed  Google Scholar 

  • Sankri-Tarbichi AG, Rowley JA, Badr MS. Expiratory pharyngeal narrowing during central hypocapnic hypopnea. Am J Respir Crit Care Med. 2009;179:313–9.

    Article  PubMed  Google Scholar 

  • Smales ET, Edwards BA, Deyoung PN, et al. Trazodone effects on obstructive sleep apnea and non-rem arousal threshold. Ann Am Thorac Soc. 2015;12:758–64.

    Article  PubMed  PubMed Central  Google Scholar 

  • Stanchina M, Robinson K, Corrao W, Donat W, Sands S, Malhotra A. Clinical use of loop gain measures to determine continuous positive airway pressure efficacy in patients with complex sleep apnea. A pilot study. Ann Am Thorac Soc. 2015;12:1351–7.

    Article  PubMed  Google Scholar 

  • Taranto Montemurro L, Floras JS, Millar PJ, et al. Inverse relationship of subjective daytime sleepiness to sympathetic activity in patients with heart failure and obstructive sleep apnea. Chest. 2012;142:1222–8.

    Article  PubMed  Google Scholar 

  • Taranto Montemurro L, Floras JS, Picton P, et al. Relationship of heart rate variability to sleepiness in patients with obstructive sleep apnea with and without heart failure. J Clin Sleep Med. 2014;10:271–6.

    PubMed  PubMed Central  Google Scholar 

  • Terrill PI, Edwards BA, Nemati S, et al. Quantifying the ventilatory control contribution to sleep apnoea using polysomnography. Eur Respir J. 2015;45:408–18.

    Article  PubMed  Google Scholar 

  • Terzano MG, Mancia D, Salati MR, Costani G, Decembrino A, Parrino L. The cyclic alternating pattern as a physiologic component of normal NREM sleep. Sleep. 1985;8:137–45.

    CAS  PubMed  Google Scholar 

  • Terzano MG, Parrino L, Boselli M, Dell’Orso S, Moroni M, Spaggiari MC. Changes of cyclic alternating pattern (CAP) parameters in situational insomnia under brotizolam and triazolam. Psychopharmacology (Berl). 1995;120:237–43.

    Article  CAS  Google Scholar 

  • Thomas RJ. Cyclic alternating pattern and positive airway pressure titration. Sleep Med. 2002;3:315–22.

    Article  PubMed  Google Scholar 

  • Thomas RJ. Alternative approaches to treatment of Central Sleep Apnea. Sleep Med Clin. 2014;9:87–104.

    Article  PubMed  PubMed Central  Google Scholar 

  • Thomas RJ, Mietus JE, Peng CK, Goldberger AL. An electrocardiogram-based technique to assess cardiopulmonary coupling during sleep. Sleep. 2005;28:1151–61.

    PubMed  Google Scholar 

  • Thomas RJ, Mietus JE, Peng CK, et al. Differentiating obstructive from central and complex sleep apnea using an automated electrocardiogram-based method. Sleep. 2007a;30:1756–69.

    PubMed  PubMed Central  Google Scholar 

  • Thomas RJ, Tamisier R, Boucher J, et al. Nocturnal hypoxia exposure with simulated altitude for 14 days does not significantly alter working memory or vigilance in humans. Sleep. 2007b;30:1195–203.

    PubMed  PubMed Central  Google Scholar 

  • Thomas RJ, Weiss MD, Mietus JE, Peng CK, Goldberger AL, Gottlieb DJ. Prevalent hypertension and stroke in the Sleep Heart Health Study: association with an ECG-derived spectrographic marker of cardiopulmonary coupling. Sleep. 2009;32:897–904.

    PubMed  PubMed Central  Google Scholar 

  • Thomas RJ, Mietus JE, Peng CK, et al. Relationship between delta power and the electrocardiogram-derived cardiopulmonary spectrogram: possible implications for assessing the effectiveness of sleep. Sleep Med. 2014;15:125–31.

    Article  PubMed  Google Scholar 

  • Walker JM, Farney RJ, Rhondeau SM, et al. Chronic opioid use is a risk factor for the development of central sleep apnea and ataxic breathing. J Clin Sleep Med. 2007;3:455–61.

    PubMed  PubMed Central  Google Scholar 

  • Weiss MD, Tamisier R, Boucher J, et al. A pilot study of sleep, cognition, and respiration under 4 weeks of intermittent nocturnal hypoxia in adult humans. Sleep Med. 2009;10:739–45.

    Article  PubMed  PubMed Central  Google Scholar 

  • Wellman A, Malhotra A, Jordan AS, Stevenson KE, Gautam S, White DP. Effect of oxygen in obstructive sleep apnea: role of loop gain. Respir Physiol Neurobiol. 2008;162:144–51.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  • Wellman A, Edwards BA, Sands SA, et al. A simplified method for determining phenotypic traits in patients with obstructive sleep apnea. J Appl Physiol (1985). 2013;114:911–22.

    Article  CAS  Google Scholar 

  • Xie A, Bedekar A, Skatrud JB, Teodorescu M, Gong Y, Dempsey JA. The heterogeneity of obstructive sleep apnea (predominant obstructive vs pure obstructive apnea). Sleep. 2011;34:745–50.

    PubMed  PubMed Central  Google Scholar 

  • Younes M, Hanly PJ. Immediate postarousal sleep dynamics: an important determinant of sleep stability in obstructive sleep apnea. J Appl Physiol (1985). 2016;120:801–8.

    Article  Google Scholar 

  • Younes M, Ostrowski M, Soiferman M, et al. Odds ratio product of sleep EEG as a continuous measure of sleep state. Sleep. 2015;38:641–54.

    PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgments

Joseph Mietus, B.S, (deceased) developer of the original cardiopulmonary coupling software, and who performed some of the ECG analysis.

APPLES

Acknowledgment List

APPLES was funded by contract 5UO1-HL-068060 from the National Heart, Lung and Blood Institute. The APPLES pilot studies were supported by grants from the American Academy of Sleep Medicine and the Sleep Medicine Education and Research Foundation to Stanford University and by the National Institute of Neurological Disorders and Stroke (N44-NS-002394) to SAM Technology.

In addition, APPLES investigators gratefully recognize the vital input and support of Dr. Sylvan Green who died before the results of this trial were analyzed, but was instrumental in its design and conduct.

ADMINISTRATIVE CORE

Clete A. Kushida, M.D., Ph.D, Deborah A. Nichols, M.S., Eileen B. Leary, B.A., RPSGT, Pamela R. Hyde, M.A., Tyson H. Holmes, Ph.D., Daniel A. Bloch, Ph.D., William C. Dement, M.D., Ph.D.

DATA COORDINATING CENTER

Daniel A. Bloch, Ph.D., Tyson H. Holmes, Ph.D., Deborah A. Nichols, M.S., Rik Jadrnicek, Microflow, Ric Miller, Microflow, Usman Aijaz, M.S., Aamir Farooq, Ph.D., Darryl Thomander, Ph.D., Chia-Yu Cardell, RPSGT, Emily Kees, Michael E. Sorel, M.P.H., Oscar Carrillo, RPSGT, Tami Crabtree, M.S., Booil Jo, Ph.D., Ray Balise, Ph.D., Tracy Kuo, Ph.D.

CLINICAL COORDINATING CENTER

Clete A. Kushida, M.D., Ph.D., William C. Dement, M.D., Ph.D., Pamela R. Hyde, M.A., Rhonda M. Wong, B.A., Pete Silva, Max Hirshkowitz, Ph.D., Alan Gevins, D.Sc., Gary Kay, Ph.D., Linda K. McEvoy, Ph.D., Cynthia S. Chan, B.S., Sylvan Green, M.D.

CLINICAL CENTERS

Stanford University

Christian Guilleminault, M.D., Eileen B. Leary, B.A., RPSGT, David Claman, M.D., Stephen Brooks, M.D., Julianne Blythe, P.A.-C, RPSGT, Jennifer Blair, B.A., Pam Simi, Ronelle Broussard, B.A., Emily Greenberg, M.P.H., Bethany Franklin, M.S., Amirah Khouzam, M.A., Sanjana Behari Black, B.S., RPSGT, Viola Arias, RPSGT, Romelyn Delos Santos, B.S., Tara Tanaka, Ph.D.

University of Arizona

Stuart F. Quan, M.D., James L. Goodwin, Ph.D., Wei Shen, M.D., Phillip Eichling, M.D., Rohit Budhiraja, M.D., Charles Wynstra, M.B.A., Cathy Ward, Colleen Dunn, B.S., Terry Smith, B.S., Dane Holderman, Michael Robinson, B.S., Osmara Molina, B.S., Aaron Ostrovsky, Jesus Wences, Sean Priefert, Julia Rogers, B.S., Megan Ruiter, B.S., Leslie Crosby, B.S., R.N.

St. Mary Medical Center

Richard D. Simon, Jr., M.D., Kevin Hurlburt, RPSGT, Michael Bernstein, M.D., Timothy Davidson, M.D., Jeannine Orock-Takele, RPSGT, Shelly Rubin, M.A., Phillip Smith, RPSGT, Erica Roth, RPSGT, Julie Flaa, RPSGT, Jennifer Blair, B.A., Jennifer Schwartz, B.A., Anna Simon, B.A., Amber Randall, B.A.

St. Luke’s Hospital

James K. Walsh, Ph.D., Paula K. Schweitzer, Ph.D., Anup Katyal, M.D., Rhody Eisenstein, M.D., Stephen Feren, M.D., Nancy Cline, Dena Robertson, R.N., Sheri Compton, R.N., Susan Greene, Kara Griffin, M.S., Janine Hall, Ph.D.

Brigham and Women’s Hospital

Daniel J. Gottlieb, M.D., M.P.H., David P. White, M.D., Denise Clarke, B.Sc., RPSGT, Kevin Moore, B.A., Grace Brown, B.A., Paige Hardy, M.S., Kerry Eudy, Ph.D., Lawrence Epstein, M.D., Sanjay Patel, M.D. *Sleep HealthCenters for the use of their clinical facilities to conduct this research

CONSULTANT TEAMS

Methodology Team: Daniel A. Bloch, Ph.D., Sylvan Green, M.D., Tyson H. Holmes, Ph.D., Maurice M. Ohayon, M.D., D. Sc., David White, M.D., Terry Young, Ph.D.

Sleep-Disordered Breathing Protocol Team: Christian Guilleminault, M.D., Stuart Quan, M.D., David White, M.D.

EEG/Neurocognitive Function Team: Jed Black, M.D., Alan Gevins, D.Sc., Max Hirshkowitz, Ph.D., Gary Kay, Ph.D., Tracy Kuo, Ph.D.

Mood and Sleepiness Assessment Team: Ruth Benca, M.D., Ph.D., William C. Dement, M.D., Ph.D., Karl Doghramji, M.D., Tracy Kuo, Ph.D., James K. Walsh, Ph.D.

Quality of Life Assessment Team: W. Ward Flemons, M.D., Robert M. Kaplan, Ph.D.

ASA-NC Team: Dean Beebe, Ph.D., Robert Heaton, Ph.D., Joel Kramer, Psy.D., Ronald Lazar, Ph.D., David Loewenstein, Ph.D., Frederick Schmitt, Ph.D.

NATIONAL HEART, LUNG, AND BLOOD INSTITUTE (NHLBI)

Michael J. Twery, Ph.D., Gail G. Weinmann, M.D., Colin O. Wu, Ph.D.

DATA AND SAFETY MONITORING BOARD (DSMB)

Seven-year term: Richard J. Martin, M.D. (Chair), David F. Dinges, Ph.D., Charles F. Emery, Ph.D., Susan M. Harding M.D., John M. Lachin, Sc.D., Phyllis C. Zee, M.D., Ph.D.

Other term: Xihong Lin, Ph.D. (2 years), Thomas H. Murray, Ph.D. (1 year)

INDUSTRY SUPPORT – Philips Respironics, Inc.

Funding

To Robert J. Thomas: RC1HL099749-01 (National Heart Lung Blood Institute, USA), Beth Israel Deaconess Medical Center Chief Academic Officer’s Research Innovation Initiative

APPLES was funded by contract 5UO1-HL-068060 from the National Heart, Lung and Blood Institute. The

APPLES pilot studies were supported by grants from the American Academy of Sleep Medicine and the Sleep

Medicine Education and Research Foundation to Stanford University and by the National Institute of Neurological Disorders and Stroke (N44-NS-002394) to SAM Technology.

The funding bodies had no role in the design of the study and collection, analysis, and interpretation of data and in writing the manuscript.

Availability of data and materials

The datasets generated during and/or analysed during the current study are not publicly available, and were obtained from the APPLES investigators following a Data Agreement through the Beth Israel Deaconess Medical Center. Secondary distribution of the data is not permitted. Individuals who wish to obtain the data may initiate the process by contacting co-author Clete Kushida, M.D., the APPLES Principal Investigator.

Authors’ contributions

RJT, MTB and CY conceptualized the analysis. RJT performed the analysis and wrote the manuscript draft. CK provided access to and interpretation assistance for the APPLES data. All authors contributed to revision of the manuscript draft. All authors read and approved the final manuscript.

Competing interests

RJT reports the following: 1) Patent and license for a method to use the ECG to phenotype sleep and sleep apnea; 2) Patent to treat central and complex sleep apnea using low concentration carbon dioxide; 3) Patent submitted and licensed software in an auto-CPAP, joint work with DeVilbiss-DRIVE’ 4) General sleep medicine consulting with GLG Councils.

MTB reports the following: Funding from the Center for Integration of Medicine and Innovative Technology, the Milton Family Foundation, and currently receives funding from the Department of Neurology, the MGH-MIT Grand Challenge, and the American Sleep Medicine Foundation. He has a patent pending on a home sleep monitoring device. He has consulting and research agreements with MC10, Insomnisolv, and McKesson. He has provided expert testimony in sleep medicine.

The other authors have no declared conflicts of interest.

Consent for publication

Not Applicable. The APPLES data is de-identified, and individuals are not recognizable through the sleep hypnogram.

Ethics approval and consent to participate

Institutional Review Board Approval from the Beth Israel Deaconess Medical Center and required Data Transfer and Use Agreements were obtained prior to the analysis.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Robert Joseph Thomas.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Thomas, R.J., Shin, C., Bianchi, M.T. et al. Distinct polysomnographic and ECG-spectrographic phenotypes embedded within obstructive sleep apnea. Sleep Science Practice 1, 11 (2017). https://doi.org/10.1186/s41606-017-0012-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s41606-017-0012-9

Keywords